Package CIM14 :: Package IEC61970 :: Package Meas :: Module PotentialTransformer' :: Class PotentialTransformer
[hide private]
[frames] | no frames]

Class PotentialTransformer

                           object --+                
                                    |                
                     Element'.Element --+            
                                        |            
  Core.IdentifiedObject'.IdentifiedObject --+        
                                            |        
Core.PowerSystemResource'.PowerSystemResource --+    
                                                |    
                        Core.Equipment'.Equipment --+
                                                    |
                                                   PotentialTransformer

Instrument transformer (also known as Voltage Transformer) used to measure electrical qualities of the circuit that is being protected and/or monitored. Typically used as voltage transducer for the purpose of metering, protection, or sometimes auxiliary substation supply. A typical secondary voltage rating would be 120V.

Instance Methods [hide private]
 
__init__(self, ptClass='', accuracyClass='', nominalRatio=0.0, *args, **kw_args)
Initialises a new 'PotentialTransformer' instance.

Inherited from Core.Equipment'.Equipment: addContingencyEquipment, addCustomerAgreements, addOperationalLimitSet, getContingencyEquipment, getCustomerAgreements, getEquipmentContainer, getOperationalLimitSet, removeContingencyEquipment, removeCustomerAgreements, removeOperationalLimitSet, setContingencyEquipment, setCustomerAgreements, setEquipmentContainer, setOperationalLimitSet

Inherited from Core.PowerSystemResource'.PowerSystemResource: addAssets, addBlock, addMeasurements, addOperatingShare, addPsrLists, addReportingGroup, getAssets, getBlock, getLocation, getMeasurements, getOperatingShare, getOutageSchedule, getPSRType, getPsrLists, getReportingGroup, removeAssets, removeBlock, removeMeasurements, removeOperatingShare, removePsrLists, removeReportingGroup, setAssets, setBlock, setLocation, setMeasurements, setOperatingShare, setOutageSchedule, setPSRType, setPsrLists, setReportingGroup

Inherited from Core.IdentifiedObject'.IdentifiedObject: getModelingAuthoritySet, setModelingAuthoritySet

Inherited from object: __delattr__, __format__, __getattribute__, __hash__, __new__, __reduce__, __reduce_ex__, __repr__, __setattr__, __sizeof__, __str__, __subclasshook__

Class Variables [hide private]
  _attr_types = {'accuracyClass': <type 'str'>, 'nominalRatio': ...
  _attrs = ['ptClass', 'accuracyClass', 'nominalRatio']
  _defaults = {'accuracyClass': '', 'nominalRatio': 0.0, 'ptClas...
  _many_refs = []
  _refs = []

Inherited from Element'.Element (private): _enums

Properties [hide private]

Inherited from Core.Equipment'.Equipment: ContingencyEquipment, CustomerAgreements, EquipmentContainer, OperationalLimitSet

Inherited from Core.PowerSystemResource'.PowerSystemResource: Assets, Block, Location, Measurements, OperatingShare, OutageSchedule, PSRType, PsrLists, ReportingGroup

Inherited from Core.IdentifiedObject'.IdentifiedObject: ModelingAuthoritySet

Inherited from object: __class__

Method Details [hide private]

__init__(self, ptClass='', accuracyClass='', nominalRatio=0.0, *args, **kw_args)
(Constructor)

 

Initialises a new 'PotentialTransformer' instance.

Parameters:
  • ptClass - PT classification.
  • accuracyClass - PT accuracy classification.
  • nominalRatio - Nominal ratio between the primary and secondary voltage.
Overrides: object.__init__

Class Variable Details [hide private]

_attr_types

Value:
{'accuracyClass': <type 'str'>,
 'nominalRatio': <type 'float'>,
 'ptClass': <type 'str'>}

_defaults

Value:
{'accuracyClass': '', 'nominalRatio': 0.0, 'ptClass': ''}