Class RemoteConnectDisconnectInfo

      object --+    
               |    
Element'.Element --+
                   |
                  RemoteConnectDisconnectInfo

Details of remote connect disconnect function.

Instance Methods [hide private]
 
__init__(self, needsPowerLimitCheck=False, isEnergyLimiting=False, isArmConnect=False, energyUsageWarning=0.0, armedTimeout=0.0, energyUsageStartDateTime='', isArmDisconnect=False, needsVoltageLimitCheck=False, powerLimit=0.0, usePushbutton=False, customerVoltageLimit=0.0, energyLimit=0.0, *args, **kw_args)
Initialises a new 'RemoteConnectDisconnectInfo' instance.

Inherited from object: __delattr__, __format__, __getattribute__, __hash__, __new__, __reduce__, __reduce_ex__, __repr__, __setattr__, __sizeof__, __str__, __subclasshook__

Class Variables [hide private]
  _attr_types = {'armedTimeout': <type 'float'>, 'customerVoltag...
  _attrs = ['needsPowerLimitCheck', 'isEnergyLimiting', 'isArmCo...
  _defaults = {'armedTimeout': 0.0, 'customerVoltageLimit': 0.0,...

Inherited from Element'.Element (private): _enums, _many_refs, _refs

Properties [hide private]

Inherited from object: __class__

Method Details [hide private]

__init__(self, needsPowerLimitCheck=False, isEnergyLimiting=False, isArmConnect=False, energyUsageWarning=0.0, armedTimeout=0.0, energyUsageStartDateTime='', isArmDisconnect=False, needsVoltageLimitCheck=False, powerLimit=0.0, usePushbutton=False, customerVoltageLimit=0.0, energyLimit=0.0, *args, **kw_args)
(Constructor)

 

Initialises a new 'RemoteConnectDisconnectInfo' instance.

Parameters:
  • needsPowerLimitCheck - True if load limit must be checked to issue an immediate disconnect (after a connect) if load is over the limit.
  • isEnergyLimiting - True if the energy usage is limited and the customer will be disconnected if they go over the limit.
  • isArmConnect - True if the RCD switch must be armed before a connect action can be initiated.
  • energyUsageWarning - Warning energy limit, used to trigger event code that energy usage is nearing limit.
  • armedTimeout - Setting of the timeout elapsed time.
  • energyUsageStartDateTime - Start date and time to accumulate energy for energy usage limiting.
  • isArmDisconnect - True if the RCD switch must be armed before a disconnect action can be initiated.
  • needsVoltageLimitCheck - True if voltage limit must be checked to prevent connect if voltage is over the limit.
  • powerLimit - Load limit above which the connect should either not take place or should cause an immediate disconnect.
  • usePushbutton - True if pushbutton must be used for connect.
  • customerVoltageLimit - Voltage limit on customer side of RCD switch above which the connect should not be made.
  • energyLimit - Limit of energy before disconnect.
Overrides: object.__init__

Class Variable Details [hide private]

_attr_types

Value:
{'armedTimeout': <type 'float'>,
 'customerVoltageLimit': <type 'float'>,
 'energyLimit': <type 'float'>,
 'energyUsageStartDateTime': <type 'str'>,
 'energyUsageWarning': <type 'float'>,
 'isArmConnect': <type 'bool'>,
 'isArmDisconnect': <type 'bool'>,
 'isEnergyLimiting': <type 'bool'>,
...

_attrs

Value:
['needsPowerLimitCheck',
 'isEnergyLimiting',
 'isArmConnect',
 'energyUsageWarning',
 'armedTimeout',
 'energyUsageStartDateTime',
 'isArmDisconnect',
 'needsVoltageLimitCheck',
...

_defaults

Value:
{'armedTimeout': 0.0,
 'customerVoltageLimit': 0.0,
 'energyLimit': 0.0,
 'energyUsageStartDateTime': '',
 'energyUsageWarning': 0.0,
 'isArmConnect': False,
 'isArmDisconnect': False,
 'isEnergyLimiting': False,
...